TM 1-1520-238-T-7
1137
116.
CONTROLS AND INDICATORS (cont)
116
Table 111.
Flight Control System Controls and Indicators (cont)
M70-303
CPG CYCLIC STICK
PILOT CYCLIC STICK
Cyclic Stick Assembly
Collective Stick and Stabilator Manual Control Panel
SWITCH/INDICATOR
POSITION
FUNCTION
BUCS select trigger switch (CPG
only)
Press to transfer BUCS control from pilots to CPGs
LVDT when mechanical linkage is severed. Also tests
CPGs BUCS when helicopter is on the ground and rotor
brake is on.
ND/NU 3-position toggle switch,
spring-loaded to off (center)
NU
(Nose Up)
Disengages automatic mode of operation and moves
stabilator to desired attitude manually.
position
ND
(Nose Down)
Disengages automatic mode of operation and moves
stabilator to desired attitude manually.
RESET pushbutton
Press to disable audio warning tone.
Press to engage automatic mode if audio warning tone
temporary malfunction.