TM 1-1520-238-T-7
11352.2
Change 5
1188. STABILATOR MAINTENANCE OPERATIONAL CHECK (cont)
1188
Task
Result
ab. On CPG INTR LT panel (fig. 11132), rotate
INST control clockwise to BRT.
M70-197
INST
CONTROL
Figure 11132.
CPG INTR LT Panel
ac. On CPG instrument panel, check that STAB
DEG/NOM SPD placard panel (fig. 11131)
and STAB POS indicator (fig. 11126)
edge-lights are lighted.
If CPG STAB POS indicator edge-light does not light,
go to paragraph 1195.
If CPG STAB DEG/NOM SPD placard panel
edge-light does not light, go to paragraph 1193.
ad. On CPG INTR LT panel (fig. 11132), rotate
INST control counterclockwise to OFF.
NOTE
If a discrepancy is noted during the FD/LS check, perform corrective action
indicated in TM 1-1520-238-T-1. If the discrepancy still exists after performing the
corrective action required, refer to the following listed failure symptoms and
perform troubleshooting.
2. Perform stabilator FD/LS check (TM 1-1520-238-T-1).
If SCU 1 NO-GO LH CATWALK appears on HOD, go
to paragraph 11106 and perform troubleshooting.
If SCU 2 NO-GO LH CATWALK appears on HOD, go
to paragraph 11107 and perform troubleshooting.