Table 7-16. Malfunction Details - Continued
Indications presented
Required
Ref
A i r c a f t indications
Corrective
to instructor/operator
malfunction
number and related effects
action
and trainee
LT CAUT
22723
Pilot center CB panel.
Noncorrectable
Instructor:
LT CAUT appears
on CRT.
pops. Loss of power to
pilot and master caution and
warning panels.
Pilot center CB panel.
LT UTIL
22724
Noncorrectable
Instructor: LT UTIL SEC
SEC
appears on CRT.
pops. Loss of power to PLT
UTILITY LT.
EMERG
Noncorrectable
22725
Pilot center CB panel.
Instructor: EMERG HYD
HYD
appears on CRT.
pops. Loss of power to
EMERG HYD switch at both sta-
tions. Accumulator cannot
be used to control movements.
TRIM
22726
Pilot center CB panel.
Instructor: TRIM appears on
Noncorrectable
CRT.
pops. Loss of power to
indicated system. HSI HDG
flag is in view.