TM 1-1520-238-23
6-388
6.88.
QUILL HOUSING/HYDRAULIC PUMP SEAL DRAIN TUBE REMOVAL/INSTALLATION continued
e. Install drain tube lower section (14).
(1) Position clamps (17) and (20) on drain tube
(14).
(2) Insert lower end of drain tube (14) through
grommet (23).
(3) Position drain tube (14) on tee (8).
(4) Hand tighten nut (22).
(5) Position spacer (16) between lower clamp
(17) and clip (18). Install screw (15).
(6) Position upper clamp (20) on clip (21). Install
screw (19).
(7) Hold tee (8) and tighten nut (22).
f. Inspect (QA).
g. Secure access doors T250L, T250R, T290L,
T290R, and L325; install panels L200 and
R200 (para 2.2).
h. Install ammunition storage magazine
(TM 9-1090-208-23).
END OF TASK
M04-2300-5
8
22
14
14
21
20
19
14
15
16
17
23
18