TM 1-1520-238-23
11-854
11.193.
ASE PANEL SWITCH REPLACEMENT (AVIM) continued
c. Install connector and post assembly (1) on
panel (2).
(1) Coat threads of screws (3) with sealing com-
pound. Use sealing compound (item 167,
App F) and brush (item 34, App F).
(2) Install three screws (3) through panel (2) into
connector and post assembly (1).
d. Inspect (QA).
e. Install ASE panel light indicating panel (para
11.192).
END OF TASK
3
2
1
M04-1750-3