TB 1-1520-251-20-13
9.36
Remove the protective cap at the cartridge discharge point.
9.37
Install a new, clean, mixing nozzle on the adhesive cartridge.
9.38
Advance the plunger to inject the adhesive product into the mixing nozzle.
9.39 Put a bead of the adhesive approximately 3/4" diameter and 3/8" thick on a lint free wipe. This will
prevent the use of the part of the adhesive that may not ne properly mixed.
NOTE
The application and distribution of the adhesive should be completed in less
than 10 minutes.
9.40 Start a thin bead of the adhesive near the top of the surface and apply around the full circumference
9.41
Begin spreading the adhesive before any begins to drop off.
CAUTION
Use a lint free swab to spread the adhesive evenly over the entire
flange edge surface. A swab should be discarded if the adhesive may
drip off. Several swabs may be required to complete the task.
9.42 Additional adhesive is to be added to the flange edge to proved enough material to spread completely
over the surface.
9.43 Use a fresh swab and spread a small amount of adhesive, evenly, on the bottom face of the generator
flange.
9.44 Assemble the flange ring onto the generator flange edge with the lip put under the bottom flange face
and the split aligned with the marks placed in step 9.25.
9.45
With hand pressure, work the ring into position and push out any excess adhesive from beneath the
ring.
9.46
Wipe and remove the excess adhesive with the cotton swabs. Slight adhesive residue is acceptable.
9.47 Make sure the position of the ring split is aligned to the relevant marks and make sure that the ring
has not slipped down on the flange edge.
9.48
Install the index, clamping, drill fixture over the flange ring.
9.49
Put the shim tab between the clamp faces at the fixture latch and tighten the latch.
9.50
Hand tighten the lower clamping plate holding screws in a star sequence until just snug. See Figure