TM 1-1520-238-23
1-26
1.15.
FUEL SERVICING - CLOSED CIRCUIT REFUELING (CCR) METHOD continued
b. Connect battery (1).
(1) Attach connector P87 (2) to receptacle
(BT1)J3 (3).
c. Set FUEL QTY IND switch (4) to ON.
d. Set REFUEL VALVE switch (5) to OPEN.
(1) Check that OPEN indicator (6) is lighted.
(2) Refer to TM 1-1520-238-T if indicator (6)
does not light.
e. Set FWD TNK switch (7) to CLOSE.
f. Set AFT TNK switch (8) to CLOSE.
GO TO NEXT PAGE
M04-1593-2
3
2
1
1
M04-1593-3
8
6
M04-1593-4
5
7
4