TM 1-1520-238-23
1-33
1.16.
FUEL SERVICING SINGLE POINT ADAPTER (SPA) METHOD continued
e. Connect single point adapter nozzle (7) to
adapter (8).
(1) Connect nozzle ground plug (9) to grounding
receptacle (10).
(2) Remove cap (11) from adapter (8).
(3) Connect nozzle (7) to adapter (8) and turn
clockwise until it locks.
CAUTION
To prevent damage to the fuel system, do
not exceed 50 psi fueling pressure.
f. To start refueling, lift valve handle (12) to
OPEN position.
g. Place FWD and AFT TNK LEVEL CONT
VALVES switches (13) to CLOSE.
CAUTION
The fuel system may be damaged if FWD
CLOSED and AFT CLOSED indicators
do not light within 8 seconds after fuel
servicing begins. If indicators do not light,
automatic fuel shutoff has not actuated.
Stop fuel servicing.
h. Check that indicators FWD CLOSED and AFT
CLOSED (14) light within 8 seconds after fuel
service begins.
(1) Stop fuel servicing if indicators do not light
(TM 1-1520-238-T).
GO TO NEXT PAGE
M04-2295-5
7
12
8
12
9
7
10
9
11
8
10
M04-2295-6
14
13