TM 1-1520-238-23
1-32
1.16.
FUEL SERVICING SINGLE POINT ADAPTER (SPA) METHOD continued
b. Connect battery (1).
(1) Attach connector P87 (2) to receptacle
(BT1)J3 (3).
c. Set FUEL QTY IND switch (4) to ON.
d. Set REFUEL VALVE switch (5) to OPEN.
(1) Check that OPEN indicator (6) is lighted.
(2) Refer to TM 1-1520-238-T if indicator (6)
does not light.
GO TO NEXT PAGE
M04-2295-2
3
2
1
1
M04-2295-3
6
M04-2295-4
5
4