TM 1-1520-238-23
1-40
1.17.
FUEL SERVICING HOT RAPID CLOSED CIRCUIT REFUELING (CCR) METHOD continued
i. Service fuel tanks, as required, when notified
by pilot.
(1) To refuel, select level control valve switch
position and advisory indicator condition from
following chart:
TANKS TO BE REFUELED
FWD TNK / AFT TNK SWITCHES
BOTH
AFT ONLY
FWD ONLY
AFT TANK
OPEN
OPEN
CLOSED
LEVEL CONT VALVES
FWD TANK
OPEN
CLOSED
OPEN
AFT CLOSED
OFF
OFF
ON
INDICATORS
FWD CLOSED
OFF
ON
OFF
CAUTION
The fuel system may be damaged if air
does not vent from fuel cells during ser-
vicing. Stop fuel servicing if air does not
escape from vent tubes.
j. Check vent tubes (14) and (15) for escaping
air.
k. Stop fuel servicing when notified by pilot or
when automatic fuel shutoff has occurred.
NOTE
FWD CLOSED and AFT CLOSED indi-
cators will light when fuel cell is full and
automatic shutoff has occurred.
GO TO NEXT PAGE
15
14
M04-1844-5