TM 1-1520-238-23
1-41
1.17.
FUEL SERVICING HOT RAPID CLOSED CIRCUIT REFUELING (CCR) METHOD continued
l. Disconnect nozzle (8) from adapter (9).
(1) Move handle (13) to OFF.
(2) Stop refueling pump.
(3) Remove nozzle (8) from adapter (9).
(4) Disconnect nozzle ground plug (10) from
grounding receptacle (11).
(5) Install cap (12) on adapter (9).
NOTE
Notify pilot if indicators remain lighted.
m. Set LEVEL CONT VALVES switches FWD TNK
(4) and AFT TNK (5) to OPEN.
(1) Check that indicators FWD CLOSED (6) and
AFT CLOSED (7) are not lighted.
NOTE
Refueling panel door will not close if ei-
ther or both LEVEL CONT VALVES
switches are in CLOSE.
n. Set REFUEL VALVE switch (2) to CLOSE.
(1) Check that OPEN indicator (3) is not lighted.
(2) Refer to TM 1-1520-238-T if indicator (3) re-
mains lighted.
o. Set FUEL QTY IND switch (1) to OFF.
p. Secure access door R160; install cover R180
(para 2.2).
q. Remove static ground lines (FM 10-68).
r. Disconnect headset and microphone (para
1.134).
END OF TASK
M04-1844-6
10
11
8
13
9
12
9
12
M04-1844-7
3
2
5
6
1
7
4