TM 1-1520-238-23
1-65
1.22.
FUEL SYSTEM VENTING continued
e. Place NO. 1 PWR lever (4) in FLY.
(1) Raise stop release lever (5).
(2) Move lever (4) to LOCKOUT.
f. When fuel stops draining, move NO. 1 PWR
lever (4) to OFF.
(1) Move lever (4) to idle.
(2) Raise stop release lever (5).
(3) Move lever (4) to OFF.
g. Place pail under No. 2 engine nacelle drain
manifold (6).
(1) Ground pail to airframe.
GO TO NEXT PAGE
M04-1603-4
4
5
5
4
M04-1603-5
6
UTILITY PAIL