TM 1-1520-238-23
1-70
1.23.
FUEL SYSTEM PRIMING continued
o. Place No. 2 PWR lever (11) in FLY.
(1) Raise stop release lever (12).
(2) Move lever (11) to LOCKOUT.
p. Observe fuel draining from manifold.
(1) Ensure fuel flow is steady.
q. Move No. 2 PWR lever (11) to OFF.
(1) Move lever (11) to IDLE.
(2) Raise stop release lever (12).
(3) Move lever (11) to OFF.
GO TO NEXT PAGE
M04-1596-6
11
11
12
12