TM 1-1520-238-23
1-128.2
Change 5
1.41.
MAIN LANDING GEAR SHOCK STRUT SERVICE FLUID continued
NOTE
Fluid pressure not to exceed 30 PSI dur-
ing filling.
l. Fill shock strut (1) with hydraulic fluid.
(1) Fill shock strut (1) until overflow into pail is
free of all air bubbles. Use hydraulic servicing
unit and hydraulic fluid (item 93, App F).
m. Close valve (17). Rotate valve (17) counterclock-
wise to close.
n. Disconnect hydraulic servicing unit hose (11)
from check valve (12). Torque cap (13) to 135
INCH-POUNDS.
(1) Hold check valve (12).
(2) Loosen nut (14). Remove hose (11) from
check valve (12).
(3) Install cap (13).
(4) Torque cap (13) to 135 INCH-POUNDS. Use
torque wrench.
GO TO NEXT PAGE
M04-2782-12
1
17
RIGHT STRUT SHOWN
12
14
11
M04-2782-9A
M04-2782-10A
13