TM 1-1520-238-23
1-198
1.57.
HELICOPTER SAFETY PROCEDURES continued
M04-1638-7
21
PILOT STATION
21
22
23
25
26
27
24
28
29
29
29
1.57.4
Pilot Station Safe - continued
Identification
Location
Set To
(5) Pilot left console
(a) L OUTBD, L INBD, R INBD,
R OUTBD (21)
STORES JETT panel
OFF; covers down
(b) BATT/EXT PWR (22)
ELEC PWR panel
OFF
(c) GEN 1, GEN 2 switches (23)
ELEC PWR panel
OFF
(d) RTR BRK switch (24)
Pilot power quadrant
LOCK
(e) MASTER IGN switch (25)
Pilot power quadrant
OFF
(f) ENG START ENG 1 switch
ENG START ENG 2 switch (26)
Pilot power quadrant
OFF
(g) PWR levers (27)
Pilot power lever panel
OFF
(h) FUEL ENG 1 and
FUEL ENG 2 switch (28)
FUEL panel
OFF
(i) ANTI-ICE panel (29)
ANTI-ICE panel
OFF
GO TO NEXT PAGE