TM 1-1520-238-23
2-221
2.65.
PILOT STATION ACCESS DOOR STRUT PULLEY REMOVAL/INSTALLATION continued
d. Remove nut (5) and screw (6) from cylinder
(1).
e. Swing out strut pulley (7) and remove from
twisted cable (8) and cylinder (1).
2.65.4. Cleaning
a. Clean sealing compound residue (para 1.47).
b. Wipe attaching areas of cylinder with a clean
rag.
2.65.5. Inspection
a. Check attaching points of cylinder for exces-
sive wear (para 2.11).
2.65.6. Installation
a. Install strut pulley (7) in cylinder (1).
(1) Install pulley (7) in twisted cable (8).
(2) Swing pulley (7) into cylinder (1).
b. Install screw (6) and nut (5) in cylinder (1).
(1) Apply sealant to threads of screw (6). Use
sealing compound (item 169, App F).
(2) Install screw (6) and nut (5) in cylinder (1).
c. Install cylinder (1) on rod (2).
(1) Install cylinder (1), washer (4), and nut (3) on
rod (2).
d. Close pilot station access door.
e. Inspect (QA).
END OF TASK
M04-2706-3
5
1
6
1
M04-2706-4
8
7
1
5
6
M04-2706-5
VIEW ROTATED
2
1
3
4
M04-2706-6