EMERGENCY POWER CHECK PANEL REMOVAL/INSTALLATION continued
e. Detach connector P175 (4) from panel recep-
tacle J1 (5).
4.138.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
4.138.5. Inspection
a. Check panel for cracks. None allowed.
b. Check panel for corrosion (para 1.49).
c. Check connector P175 for bent or missing
pins (TM 55-1500-323-24).
4.138.6. Installation
a. Attach connector P175 (4) to receptacle J1 (5).
b. Install panel (1) in console (2).
(1) Lock two turnlock fasteners (3).
c. Inspect (QA).
d. Perform power plants maintenance operation-
al check (engine No. 1) (TM 1-1520-238-T).
END OF TASK
M0-1064-3