TM 1-1520-238-23
4-440
4.139.
EMERGENCY POWER CHECK PANEL DISASSEMBLY/ASSEMBLY (AVIM) continued
4.139.4. Cleaning
a. Clean removed and attaching parts (para
1.47).
4.139.5. Inspection
a. Check removed and attaching parts for dam-
age.
b. Check connectors and terminals for damage
(TM 55-1500-323-24).
c. Check wires for wear, cuts, breaks, burned
insulation,
and
other
contamination
(TM 55-1500-323-24).
d. Check removed and attaching parts for corro-
sion (para 1.49).
4.139.6. Assembly
a. Install lead (50) on panel (2).
(1) Install screw (47) on panel (2).
(2) Install washer (53), lockwasher (52), nut (51),
wire lead (50), washer (49), and nut (48).
b. Perform
electrical
bond
check
(TM 55-1500-323-24).
(1) Bond shall be 0.1 OHM or less. Use
ohmmeter.
c. Install connector (41) on panel (2).
(1) Install connector (41) through panel (2).
(2) Install washer (46), lockwasher (45), and nut
(44).
d. Install wire (40) on connector (41).
(1) Install screw (42) through washer (43), lead
(40), and connector (41).
GO TO NEXT PAGE
M04-3631-5
40
41
39
47
2
53
52
51
50
49
48
46
45
44
42
43