TM 1-1520-238-23
4-700
4.190.
PILOT POWER QUADRANT PANEL ENG START ADVISORY SWITCH REMOVAL/INSTALLATION
(AVIM) continued
b. Depin three wires (6) from connector J1 (7).
(1) Identify wires (6).
(2) Depin three wires (6) from connector J1 (7)
(TM 55-1500-323-24).
(3) Remove connector J1 (7) with bracket (1).
c. Remove advisory light (8) from panel (2).
(1) Pull out lens (9) and move to one side.
(2) Loosen two screws (10).
(3) Hold spacer (11). Pull sleeve (12) from advi-
sory light (8).
(4) Pull advisory light (8) and attaching wires (6)
from panel (2).
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
d. Desolder wires (6) from advisory light (8).
(1) Identify three wires (6).
(2) Remove insulation sleeving (13).
(3) Desolder wires (6). Use soldering iron
(TM 55-1500-323-24).
GO TO NEXT PAGE
6
7
1
M04-3335-8
M04-3335-2
9
11
10
2
8
2
12
M04-3335-3
6
8
9
11
13
M04-3335-9
6
8
8
6