TM 1-1520-238-23
5-124
5.25.
MAIN ROTOR PITCH HOUSING REMOVAL continued
5.25.3. Removal
CAUTION
Convoluted covering on wire harness is
fragile. Do not bend or crush while re-
moving harness. Flexibility will be lost.
a. Remove clamps (1) and harness (2) from main
rotor pitch housing (3).
(1) Remove three nuts (4) and washers (5).
(2) Remove three screws (6) and washers (7).
(3) Remove three clamps (1) from harness (2).
b. Remove clamp (1) and harness (2) from angle
bracket (8).
(1) Remove screw (9), washer (10), and clamp
(1).
(2) Remove clamp (1) from harness (2).
GO TO NEXT PAGE
M04-236-1
M04-236-5
5
1
1
2
4
7
1
6
3
9
10
1
2
8
2
8
M04-236-6
w