TM 1-1520-238-23
7-316
7.79.
UTILITY HYDRAULIC GSE PANEL REMOVAL/INSTALLATION continued
7.79.3. Removal
a. Remove dust caps (1) from utility hydraulic
GSE panel (2).
(1) Hold nut (3).
(2) Remove screw (4), spacer (5), and two wash-
ers (6) from dust cap (1) cables. Remove nut
(3).
(3) Remove dust caps (1).
b. Remove panel (2) from mounting bracket (7).
(1) Remove seven screws (8) and washers (9).
(2) Remove panel (2).
7.79.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
7.79.5. Inspection
a. Check panel for dents, nicks, and cracks (para
7.56).
b. Check removed and attaching parts for corro-
sion (para 1.49).