TM 1-1520-238-23
7-317
7.79.
UTILITY HYDRAULIC GSE PANEL REMOVAL/INSTALLATION continued
7.79.6. Installation
a. Install panel (2) on mounting bracket (7).
(1) Position panel (2) on bracket (7) to aline
screw holes.
(2) Install seven screws (8) and washers (9).
b. Install dust caps (1) on panel (2).
(1) Insert spacer (5) through dust cap (1) cables.
(2) Install screw (4) through two washers (6) and
spacer (5) into panel (2).
(3) Install nut (3).
c. Inspect (QA).
d. Install utility hydraulic accumulator nitrogen
manifold (para 7.85).
e. Install utility hydraulic GSE return coupling
(para 7.81).
f. Install utility hydraulic GSE pressure coupling
(para 7.80).
g. Service utility hydraulic accumulator (para
1.36).
h. Bleed utility hydraulic system (para 1.35).
i. Service utility hydraulic system (para 1.34).
j. Perform hydraulic system leak check (para
7.2).
k. Secure access door R325 (para 2.2).
END OF TASK
3
5
6
1
6
4
2
1
7
9
8
M04-871-4