TM 1-1520-238-23
7-336
7.85.
UTILITY HYDRAULIC ACCUMULATOR NITROGEN MANIFOLD
REMOVAL/INSTALLATION continued
7.85.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
7.85.5. Inspection
a. Check manifold, pressure gage, and fill/bleed
valve for nicks, dents, cracks, and stripped or
damaged threads (para 7.56).
b. Check tube for nicks, dents, cracks, and
stripped or damaged threads (para 7.56).
c. Check removed and attaching parts for corro-
sion (para 1.49).
7.85.6. Installation
a. Install manifold (1) on panel (2).
(1) Aline manifold (1) on panel (2).
(2) Install two screws (6) and washers (7)
through panel (2) and manifold (1).
(3) Hold two screws (6). Install two new locknuts
(5) on screws (6).
(4) Install tube (3) on manifold (1). Install nut (4).
b. Inspect (QA).
c. Install utility hydraulic accumulator nitrogen
manifold pressure gage (para 7.84).
d. Install utility hydraulic accumulator nitrogen
manifold fill/bleed valve (para 7.83).
e. Service utility hydraulic accumulator (para
1.36).
f. Service utility hydraulic system (para 1.34).
g. Secure access door R325 (para 2.2).
END OF TASK
M04-3594-4
6
7
4
1
5
2
3