TM 1-1520-238-23
7-341
7.87.
UTILITY HYDRAULIC ACCUMULATOR CHECK VALVE REPLACEMENT continued
7.87.3. Removal
a. Remove check valve (1).
(1) Place rags under check valve (1) to catch
hydraulic fluid spills.
(2) Hold check valve (1). Remove nuts (2) and
(3) from check valve (1).
(3) Remove and discard check valve (1).
7.87.4. Cleaning
a. Wipe attaching parts with a clean rag.
7.87.5. Inspection
a. Check nuts for nicks, dents, scratches, and
stripped or damaged threads (para 7.56).
b. Check attaching parts for corrosion (para
1.49).
7.87.6. Installation
a. Install new check valve (1) with arrow on valve
pointing toward tee union (4).
(1) Lubricate threads of check valve (1). Use
clean hydraulic fluid (item 92, App F).
(2) Hold check valve (1). Install nuts (2) and (3)
on check valve (1).
GO TO NEXT PAGE
3
1
2
M04-3595-2
3
1
2
M04-3595-3
4