TM 1-1520-238-23
7-455
7.118.
AIR PARTICLE SEPARATOR FILTER REPLACEMENT continued
7.118.3. Removal
a. Remove filter (1) from air particle separator
(2).
(1) Unlock two turnlock fasteners (3) and remove
eductor tube assembly (4) from separator (2).
NOTE
Eductor tube and door are retained to
particle separator assembly by lanyards.
(2) Unlock latches (5) from door (6).
(3) Remove door (6).
(4) Remove and discard filter (1) from extension
cavity in separator (2).
7.118.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
7.118.5. Inspection
a. Check removed and attaching parts for dam-
age (para 7.114).
b. Check inside cavity for debris (para 7.114).
c. Check removed and attaching parts for corro-
sion (para 1.49).
GO TO NEXT PAGE
M04-3761-2
1
2
5
4
3
6