AIRCRAFT AIR PRESSURE FLUID MANIFOLD INSTALLATION continued
7.138.3. Installation
a. Lubricate new packings (1), (2), (3), (4), (5), (6),
and (7). Use petrolatum (item 138, App F).
b. Install packings (1), (2), and (3) on tee (8), tube
(9), and tube (10).
c. Install packings (4), (5), and (6) on manifold
(11).
CAUTION
To prevent damage to SDC, check valve
must be installed with hinge vertical and
arrow pointing toward manifold.
d. Install check valve (12) in manifold (11).
(1) Install packing (7) in manifold (11).
(2) Install check valve (12) vertically with the ar-
row pointing toward manifold (11).
e. Install manifold (11) on tube (9), (10), and tee
(8).
(1) Install couplings (13), (14), and (15).
(2) Place coupling (16) in position on bleed air
shutoff valve (17) and manifold (11). Install
nut (18).
f. Install clamp (19) and two screws (20).
g. Install clamp (21).
(1) Left side: install screw (22) through washer
(23), clamp (21), washer (24), spacer (25),
and washer (26) into structure.
(2) Right side: install screw (22) through washer
(23), clamp (21), washer (26), and spacer
(25) into structure.
GO TO NEXT PAGE