TM 1-1520-238-23
7-530
7.138.
AIRCRAFT AIR PRESSURE FLUID MANIFOLD INSTALLATION continued
l. Install adapter branch tube (42) on manifold
(11).
(1) Lubricate fitting (43). Use damping fluid
(item 69, App F).
(2) Rotate tube (42) toward manifold (11).
(3) Hold fitting (43). Install nut (44).
(4) Hold tee (45). Tighten nut (46).
NOTE
If manifold was replaced, go to step m. If
manifold was reinstalled, go to step n.
m. Install cap (47) on fitting (48).
(1) Hold fitting (48). Use open end wrench.
(2) Install cap (47).
n. Inspect (QA).
o. Perform pressurized air system leak check
(para 7.115).
p. Install forward two catwalk sections (para
2.84).
q. Secure access doors T250L, T250R, T290L,
T290R and L325 (para 2.2).
END OF TASK
48
11
45
46
42
43
44
M04-086-6
47