7.152.
PRESSURIZED AIR SYSTEM LEFT AND RIGHT AUXILIARY FUEL QUICK-DISCONNECT BRANCH
TUBES AND COUPLINGS REMOVAL/INSTALLATION continued
NOTE
This task is typical for left and right
branch tubes.
If extended range kit is installed, en-
sure air tubes are disconnected from
coupling assembly.
7.152.3. Removal
a. Remove right branch tube (1) from coupling
assembly (2).
(1) Hold coupling (2) from outside of fuselage (3).
(2) Remove nut (4) from inside of ammunition
bay.
b. Remove coupling assembly (2) from fuselage
(3).
(1) Hold coupling (2). Remove nut (5) and wash-
er (6) from coupling (2).
(2) Remove coupling (2).
c. Remove tube (1).
(1) Remove bolt (7), washer (8), clamp (9),
spacer (10), and clamp (11) from bracket
(12).
(2) Remove two bolts (13), washers (14), and
clamps (15) from brackets (16).
(3) Hold tee (17). Remove nut (18).
(4) Remove tube (1).