TM 1-1520-238-23
7-588
7.156.
ICE DETECTOR WARM AIR SUPPLY VALVE REPLACEMENT continued
7.156.3. Removal
a. Remove aft warm air supply tube (1) from
warm air supply valve (2).
(1) Hold reducer (3). Remove nut (4).
b. Remove center warm air supply tube (5) from
valve (2).
(1) Hold reducer (6). Remove nut (7).
c. Remove valve (2).
(1) Remove three screws (8) and washers (9).
(2) Detach connector P872 (10) from receptacle
(L50)J1 (11).
7.156.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
7.156.5. Inspection
a. Check removed and attaching parts for
crossed, burred, or stripped threads (para
7.114).
b. Check removed and attaching parts for corro-
sion (para 1.49).
GO TO NEXT PAGE
2
1
M04-3496-2
3
4
M04-3496-3
2
6
7
5
M04-3496-4
10
11
2
8
9
8
9
9