TM 1-1520-238-23
7-592
7.157.
ICE DETECTOR AFT WARM AIR SUPPLY TUBE REPLACEMENT continued
7.157.6. Installation
CAUTION
To prevent bending of the warm air sup-
ply tube, care must be used when instal-
ling tube.
a. Install tube (1) on valve (10).
(1) Lubricate threads of reducer (11) with
damping fluid (item 69, App F).
(2) Hold reducer (11). Install nut (12).
b. Install clamp (5) on bracket (6).
(1) Install clamp (5) on warm air supply tube (1).
(2) Install screw (7) through washer (8), clamp
(5), and spacer (9) to bracket (6).
c. Install tube (1) on tube (2).
(1) Lubricate threads of fitting (3) with damping
fluid (item 69, App F).
(2) Hold fitting (3). Install nut (4).
d. Inspect (QA).
e. Perform pressurized air system leak check
(para 7.115).
f. Secure access doors T250L, T250R, T290L,
T290R, and L325; install fairing T205L (para
2.2).
END OF TASK
M04-3495-5
1
11
12
10
7
8
5
9
6
1
4
3
2
M04-3495-4