TM 1-1520-238-23
6-367
6.84.
HEAT EXCHANGER PRESSURE TRANSDUCER REMOVAL/INSTALLATION continued
6.84.3. Removal
a. Enter pilot station (para 1.56). Observe all
safety precautions.
b. On pilot center circuit breaker panel, open LT
CAUT circuit breaker.
c. Enter CPG station (para 1.56). Observe all
safety precautions.
d. On CPG left console circuit breaker panel No.
1, open EMER BATT CAUT circuit breaker.
e. Detach connector P579 (1) from receptacle
J579 (2) for left side.
f. Detach connector P578 (1) from receptacle
J578 (2) for right side.
g. Identify and depin wires (3), (4), and (5) from
connector (1) (TM 55-1500-323-24).
h. Remove clamp (6).
(1) Remove screw (7) and washer (8) from clamp
(6).
(2) Remove clamp (6).
i. Remove bracket (9).
(1) Remove two screws (10) and washers (11).
(2) Remove bracket (9).