TM 1-1520-238-23
6-387
6.88.
QUILL HOUSING/HYDRAULIC PUMP SEAL DRAIN TUBE REMOVAL/INSTALLATION continued
6.88.7. Installation
a. Install seal tube (10).
(1) Position seal tube (10) on union (11).
(2) Hand tighten nut (12).
(3) Position seal tube (10) on tee (8). Install nut
(13).
(4) Tighten nut (12) on union (11).
b. Install tube (7) on tee (8).
(1) Position tube (7) on tee (8).
(2) Hand tighten nut (9).
c. Install clamp (3) on main transmission return
oil line (left side).
(1) Install spacer (6) and clamp (3).
(2) Install bolt (4) and washer (5).
d. Install quill tube (1).
(1) Position two clamps (2) on quill tube (1).
(2) Install upper end of quill tube (1) on tube (24).
Tighten clamp (2).
(3) Install lower end of quill tube (1) on tube (7).
Tighten clamp (2).
(4) Hold tee (8). Tighten nut (9).
GO TO NEXT PAGE
1
2
11
10
2
3
M04-2300-7
24
12
1
13
8
9
7
10
5
6
4