TM 1-1520-238-23
7-54
7.15.
PRIMARY HYDRAULIC MANIFOLD PRESSURE TRANSDUCER REPLACEMENT continued
c. Apply sealing compound around entire base
of transducer (1) where it contacts manifold
(2) and around four screws (3). Use sealing
compound (item 174, App F).
d. Allow sealing compound to dry for 24 HOURS
at 65 F (18 C) minimum.
e. Inspect (QA).
f. Bleed primary hydraulic system (para 1.35).
g. Service primary hydraulic system (para 1.34).
h. Perform primary hydraulic system mainte-
nance operational check (TM 1-1520-238-T).
i. Install access panel L200 (para 2.2).
END OF TASK
M04-748-4
2
3
1