TM 1-1520-238-23
7-57
7.16.
PRIMARY HYDRAULIC MANIFOLD STRAINER REPLACEMENT continued
7.16.6. Installation
a. Lubricate two new packings (9). Use clean
hydraulic fluid (item 92, App F).
b. Install two packings (9) in grooves (12) of two
new strainers (8).
NOTE
The pressure cap and return cap differ
only slightly in size. Ensure that the larger
packing and backup rings are installed on
the return cap, and the smaller packing
and backup rings are installed on the
pressure cap.
c. Lubricate new packings (4) and (5), two sets
of backup rings (6) and (7), and threads of
pressure cap (1) and return cap (2). Use clean
hydraulic fluid (item 92, App F).
d. Install packing (5) between two backup rings
(7) in groove (14) on pressure cap (1).
e. Install packing (4) between two backup rings
(6) in groove (15) on return cap (2).
GO TO NEXT PAGE
M04-754-4
8
12
9
M04-754-9
14
7
5
7
1
2
15
6
4
6