TM 1-1520-238-23
7-90
7.25.
HYDRAULIC HAND PUMP REMOVAL/INSTALLATION continued
7.25.6. Installation
NOTE
Ensure all shipping hardware is removed
from three mounting areas of new hand
pump before installation.
a. Install pump (3) on panel (14).
(1) Aline pump (3) on panel (14).
(2) Install two bolts (15) and (16) and washers
(18).
(3) Aline holes on pump (3) and support (19).
(4) Install bolt (17) and washer (18).
b. Install tube (11) on adapter (12).
(1) Lubricate threads on adapter (12). Use clean
hydraulic fluid (item 92, App F).
(2) Install nut (13) on adapter (12).
c. Install tube (8) on adapter (9).
(1) Lubricate threads on adapter (9). Use clean
hydraulic fluid (item 92, App F).
(2) Install nut (10) on adapter (9).
GO TO NEXT PAGE
M04-762-7
17
19
3
18
18
15
18
16
14
M04-762-8
8
11
10
13
9
12