TM 1-1520-238-23
7-192
Change 8
7.47.
LONGITUDINAL SERVOCYLINDER REMOVAL continued
l. Detach connector P220 (1) from receptacle
(L34)J220 (2).
m. Detach connector (L34)P219 (3) from recep-
tacle J219 (4).
(1) Remove lockwire and antichafe tubing from
connector P219 (3).
(2) Remove connector P219 (3).
n. Detach connector (L34)P408 (5) from recep-
tacle J408 (6).
(1) Remove lockwire and antichafe tubing from
connector P408 (5).
(2) Remove connector P408 (5).
o. Remove primary pressure tube (7) from adapt-
er (8).
(1) Place rags around servocylinder (9) to catch
hydraulic fluid spills.
(2) Remove nut (10).
p. Remove primary return tube (11) from adapter
(12).
(1) Remove nut (13).
q. Remove tube clamp (14).
(1) Remove screw (15), washer (16), and wire
clamp (17).
(2) Remove wire clamp (17) from wire harness
(18).
(3) Remove halves of clamp (14).
GO TO NEXT PAGE
M04-825-2
1
2
5
M04-825-11
6
4
3
M04-825-3
12
13
11
10
8
7
9
M04-825-4
18
17
15
16
14