TM 1-1520-238-23
7-194
Change 5
7.47.
LONGITUDINAL SERVOCYLINDER REMOVAL continued
NOTE
If ground cable is installed on helicopter,
go to step w. If not, go to step x.
w. Remove cable (36) from servocylinder (9).
(1) Remove sealant from screw (37), nut (38),
washer (39), and clamp (40) (para 1.47).
(2) Hold screw (37). Remove nut (38) and wash-
er (39).
(3) If replacing servocylinder (9), remove clamp
(40).
WARNING
To prevent movement of bellcrank and
possible injury, support bellcrank be-
fore disconnecting servocylinder. If
injury occurs, seek medical aid.
x. Remove rod end (41) from bellcrank (42).
(1) Remove sealant from attaching hardware
(para 1.47).
(2) Remove and discard cotter pin (43).
(3) Hold bolt (44). Use box wrench.
(4) Remove nut (45). Use box wrench.
(5) Remove bolt (44) and washer(s) (47), if
installed.
NOTE
Do not remove nylon washer unless it is
loose or excessively worn.
(6) Remove bushing (46) and nylon washer
(46.1) (if necessary).
y. Remove servocylinder (9) from bellcrank (42).
GO TO NEXT PAGE
9
37
M04-825-13
36
40
39
38
47
M04-825-9
41
44
45
43
42
9
46
42
46.1
M04-825-10A