TM 1-1520-238-23
7-295
7.73.
UTILITY HYDRAULIC MANIFOLD SOLENOID VALVE REPLACEMENT continued
CAUTION
Extreme care must be taken to prevent
foreign objects from entering open pas-
sages of manifold.
7.73.3. Removal
a. Remove valve (1) from manifold (2).
(1) Place rags under valve (1) to catch hydraulic
fluid spills.
(2) Remove four screws (3).
(3) Pull valve (1) straight out of manifold (2).
(4) Discard valve (1) and packings (4), (5), and
(6).
7.73.4. Cleaning
a. Wipe removed and attaching parts. Use cloth
(item 52, App F).
7.73.5. Inspection
a. Check manifold and screws for stripped and
damaged threads (para 7.56).
b. Check removed parts and attaching parts for
corrosion (para 1.49).
GO TO NEXT PAGE
VIEW ROTATED
M04-904-2
4
5
6
2
3
1