TM 1-1520-238-23
8-115
8.44.
HYDRAULIC PRESSURE INDICATOR REMOVAL/INSTALLATION continued
c. Remove hydraulic pressure indicator (1) from
instrument panel (2).
(1) Remove four screws (3).
(2) Pull indicator (1) from panel (2).
(3) Detach connector P746 (4) from receptacle
(M29)J1 (5).
8.44.4. Cleaning
a. Wipe mounting area and indicator with a clean
rag.
8.44.5. Inspection
a. Check indicator and instrument panel mount-
ing area for cracks, nicks, and dents (para
8.43).
b. Check indicator and instrument panel screw
holes for stripped or damaged threads (para
8.43).
8.44.6. Installation
a. Install indicator (1) in panel (2).
(1) Attach connector P746 (4) to receptacle
(M29)J1 (5).
(2) Aline indicator (1) with screw holes in panel
(2).
(3) Install four screws (3).
b. Inspect (QA).
c. Perform utility hydraulic maintenance opera-
tional check (TM 1-1520-238-T).
END OF TASK
M04-189-3
3
1
2
M04-189-4
1
4
5
2
M04-189-5
1
5
4
2
M04-189-6
3
2
1