TM 1-1520-238-23
9-137
9.39.
EXTERNAL POWER ACCESS DOOR SWITCH REMOVAL/INSTALLATION continued
9.39.6. Installation
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
a. Solder wires (6) to microswitch (1).
(1) Solder
identified
wires
(6)
(TM 55-1500-323-24). Use soldering iron and
solder (item 189, App F).
b. Install microswitch (1) on bracket (2).
(1) Install washer (5) on microswitch (1).
(2) Install microswitch (1).
(3) Install washer (4) and nut (3).
c. Inspect (QA).
d. Perform external power and ground service
utility connector maintenance operational
check (TM 1-1520-238-T).
e. Secure access door R345 (para 2.2).
END OF TASK
3
4
2
6
1
5
M04-1127-4