TM 1-1520-238-23
9-193
9.56.
AFT AVIONICS BAY DISTRIBUTION BOX TRANSFORMER T1 OR T2 REPLACEMENT
(T700-GE-701) continued
9.56.6. Installation
a. Install new ASE transformer (6).
(1) Install screw (7) and washer (8).
b. Pin red wire (3) and brown wire (4) to terminal
board (5) (TM 55-1500-323-24).
c. Pin orange wire (1) to ground stud (2)
(TM 55-1500-323-24).
d. Perform
electrical
bond
check
(TM 55-1500-323-24).
(1) Bond shall be 0.0025 OHM or less. Use ohm-
meter.
e. Inspect (QA).
f. Perform DASE maintenance operational
check (TM 1-1520-238-T).
g. Secure access door R295 (para 2.2).
END OF TASK
M04-4511-4
6
7
8
3
5
4
M04-4511-5
1
2