TM 1-1520-238-23
9-248
9.69.
PILOT EXT LT/INTR LT PANEL RELAY K1/K2 AND SOCKET XK1/XK2 REPLACEMENT
(AVIM) continued
9.69.6. Installation
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
a. Install new socket (8) on board A1 (11), if re-
moved.
(1) Install socket (8) on board (11).
(2) Solder identified wires (12) on terminals (13).
Use soldering iron and solder (item 189,
App F) (TM 55-1500-323-24).
b. Install new relay (7) on socket (8).
(1) Install relay (7) on socket (8) so that tab on
relay alines with tab on socket.
(2) Install grounding strap (10) and screw (9).
c. Install board A2 (1) on panel (2).
(1) Position three spacers (6) on board A1 (11).
(2) Position board A2 (1) on spacers (6).
(3) Install three screws (3) through lockwashers
(4), washers (5), board (1), spacers (6), board
(7), and into tube assemblies (8).
d. Inspect (QA).
END OF TASK
8
13
11
12
8
M04-5083-5
9
7
10
8
7
M04-5083-6
2
4
3
6
11
8
5
M04-5083-7
1