TM 1-1520-238-23
9-251
9.70.
PILOT EXT LT/INTR LT PANEL FORM VARIABLE RESISTOR REPLACEMENT (AVIM) continued
9.70.6. Installation
a. Install new resistor (2) on panel (4).
(1) Install washer (7) on resistor (2).
(2) Position resistor (2) so that tab (8) seats in
locator hole (9).
(3) Install lockwasher (6) and nut (5).
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
b. Solder wires (1) to resistor (2).
c. Solder identified wires (1) to terminals (3). Use
soldering iron and solder (item 189, App F)
(TM 55-1500-323-24).
d. Install pilot EXT LT/INTR LT panel light indicat-
ing panel (para 9.64).
e. Inspect (QA).
END OF TASK
1
M04-1391-3
2
5
6
9
4
8
2
7
3