TM 1-1520-238-23
9-381
9.107.
PILOT OR CPG CAUTION/WARNING AND MASTER CAUTION/WARNING PANEL LIGHT SWITCH
REPLACEMENT (AVIM)
9.107.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
9.107.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
Light duty laboratory apron (item 27, App H)
Chemical protective gloves (item 154, App H)
Adjustable air filtering respirator (item 262, App H)
25-watt electric soldering iron (item 332, App H)
Materials/Parts:
Cloth (item 52, App F)
Isopropyl alcohol (item 106, App F)
Solder (item 189, App F)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
9.106
Pilot or CPG push button cap removed
NOTE
This task is typical for pilot or CPG caution/warning and master caution/warning panel light
switches.
If replacing pilot or CPG caution/warning panel light switches, go to step b.
GO TO NEXT PAGE