TM 1-1520-238-23
9-382
9.107.
PILOT OR CPG CAUTION/WARNING AND MASTER CAUTION/WARNING PANEL LIGHT SWITCH
REPLACEMENT (AVIM) continued
9.107.3. Removal
a. Remove rear plate assembly (1) from housing
(2).
(1) Remove eight screws (3) and plate (1) from
housing (2).
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
b. Remove wiring (4) from light switch (5).
(1) Identify and desolder wiring (4) from light
switch
(5).
Use
soldering
iron
(TM 55-1500-323-24).
GO TO NEXT PAGE
M04-4216-1
3
1
2
M04-4216-2
4
5