TM 1-1520-238-23
9-387
9.108.
PILOT OR CPG CAUTION/WARNING AND MASTER CAUTION/WARNING PANEL LAMP
REPLACEMENT continued
CAUTION
To prevent damage to legends, lens
caps must be installed with TOP-to-top
and BOTTOM-to-bottom as shown.
Caps are unusable if installed incor-
rectly.
c. Remove lamp (1) from either caution/warning
or master caution warning panels (2) from pi-
lot or CPG station.
(1) Pull lens cap (3) from panel (2) and move to
one side.
(2) Remove lamp (1) from cap (3).
9.108.6. Installation
a. Install lamp (1) in panel (2).
(1) Insert lamp (1) in cap (3).
(2) Aline cap (3) with caution/warning panel (2)
and push in to seat.
b. Inspect (QA).
c. Perform pilot or CPG caution and warning
system maintenance operational check
(TM 1-1520-238-T).
END OF TASK
3
2
1
M04-1409-2
3
2
1
3
2
M04-1409-3