TM 1-1520-238-23
9-429
9.116.
CPG CAUTION/WARNING PANEL HOUSING DISASSEMBLY/ASSEMBLY (AVIM) continued
9.116.6. Assembly
a. Install connector (A157)J7 (46) on plate (5).
(1) Position connector (46) on top of plate (5) by
sliding up through plate (5) connector slot.
(2) Install two screws (47) through washers (48),
connector (46), and plate (5).
(3) Install two nuts (49) on screws (47).
b. Install connector (A157)J6 (43) on plate (5).
(1) Position connector (43) on top of plate (5) by
sliding connector (43) up through plate (5) con-
nector slot.
(2) Install two screws (44) through washers (45)
and plate (5) in connector (43).
GO TO NEXT PAGE
M04-4221-15
47
48
49
5
46
M04-4221-16
44
45
5
43