TM 1-1520-238-23
9-575
9.152.
AIR TURBINE STARTER FLOW SWITCH AND TURBINE SPEED CUTOUT FLOW SWITCH
REPLACEMENT continued
9.152.3. Removal
NOTE
Removal of air turbine starter flow switch
requires detaching connector P64 from
(A5)J1 and/or removal of the turbine
speed cutout flow switch requires detach-
ing connector P1370 from (A709)J1.
a. Detach connector P64 (1) from receptacle
(A5)J1 (2) or connector P1370 (1) from recep-
tacle (A709)J1 (2).
b. Remove switch (3).
(1) Remove two screws (4) and washers (5).
9.152.4. Cleaning
a. Wipe removed and attaching parts (para 1.47).
9.152.5. Inspection
a. Check removed and attaching parts for dam-
age (para 9.126).
b. Check wires and terminals for wear, cracks,
and cuts (para 9.126).
c. Check connectors and receptacles for cracks,
broken connections, and bent or damaged
pins (para 9.126).
d. Check removed and attaching parts for corro-
sion (para 1.49).
GO TO NEXT PAGE
4
3
2
1
5
M04-1817-3