TM 1-1520-238-23
9-584
Change 3
9.154. DATA LINK TERMINATION UNIT (DLTU) T37, T38, T39, OR T40 REPLACEMENT continued
WARNING
Do not place heater near flammable
material or allow heater to contact
skin: severe burns can result. Wear
protective equipment. If injury occurs,
seek medical aid.
NOTE
All expendables are from shield splicing
kit (item 190A, App F).
e. Splice DLTU lead (3) to wire harness lead (2).
(1) Position sleeve/marker (16) on end of lead
(3).
(2) Position insulating sleeve (17) on lead (2).
(3) Position one solder sleeve (18) on lead (2).
Position one shield splice (19) and another
solder sleeve (18) on end of lead (3).
(4) Position conductor splice (20) and insulating
sleeve (21) on longer conductor of leads (3)
or (2) for each splice connection.
(5) Place leads (3) and (2) opposite each other.
(6) Ensure insulating sleeve (21) is installed on
conductor. Crimp each conductor splice (20).
(7) Position insulating sleeve (21) over each con-
ductor splice (20).
(8) Apply heat until insulating sleeve (21) fully
shrinks on each conductor splice (20). Use
heater.
GO TO NEXT PAGE
M04-5145-15
16
3
2
17
19
21
21
18
18
2
M04-5145-16
20
20
3
21
21
M04-5145-17
20
20
21
21