TM 1-1520-238-23
10-21
10.5.
FORWARD FUEL CELL FORWARD FUEL QUANTITY TRANSMITTER
REMOVAL/INSTALLATION continued
CAUTION
Jet fuel will cause external surface of fuel
cell to swell, delaminate, and leak if al-
lowed to contact the fuel cell more than
72 HOURS. Keep jet fuel away from the
outside of fuel cells.
b. Remove forward fuel cell access panel (1) in
pilot station.
(1) Remove 28 screws (2) and washers (3).
(2) Remove panel (1).
c. Remove fuel quantity transmitter mounting
bolts (4).
(1) Remove six bolts (4) and washers (5).
d. Detach upper electrical leads (6) and (7) on
fuel cell forward fuel quantity transmitter (8).
(1) Remove screw (9), black lead (7), and clamp
(10) from transmitter (8).
(2) Remove screw (11) and white lead (6) from Hi
Z terminal (12).
GO TO NEXT PAGE
M04-324-2
2
3
1
4
5
M04-324-3
6
11
7
8
VIEW ROTATED
12
10
9